Kramer VP-730 Presentation Scaler-Switcher Firmware 1.2 Audio

Upgrading the Audio Firmware

Follow these steps to upgrade the audio firmware:

1. Double click the desktop icon: “Shortcut to FLIP.EXE”.

2. After a few seconds, the Splash screen is replaced by the “Atmel – Flip” window

3. Press the keyboard shortcut key F2 (or select the “Select” command from the Device menu, or press the integrated circuit icon in the upper right corner of the window). The “Device Selection” window appears

4. Click the button next to the name of the device and select from the list: AT89C51RD2

5. Click OK and select “Load Hex” from the File menu.

. The Open File window opens. Select the correct HEX file that contains the updated version of the firmware for VP-730/731 (for example 44M_V1p2.hex) and click Open.

7. Press the keyboard shortcut key F3 (or select the “Communication / RS232” command from the Settings menu, or press the keys: Alt SCR).

The “RS232” window appears. Change the COM port according to the configuration of your computer and select the 9600 baud rate

8. Click Connect.

In the “Atmel – Flip” window, in the Operations Flow column, the Run button is active, and the name of the chip appears as the name of the third column: AT89C51RD2.

Verify that in the Buffer Information column, the “HEX File: VP730.hex” appears.

9. Click Run.

After each stage of the operation is completed, the check box for that stage becomes colored green.

When the operation is completed, all 4 check boxes will be colored green and the status bar message: Memory Verify Pass appears

10. Close the “Atmel – Flip” window.

11. Disconnect the power on the VP-730/731.

12. If required, disconnect the rear panel AUDIO PROG. terminal block connector on the VP-730/731.

13. Release the rear panel AUDIO PROG. button, using a small screwdriver.

14. Connect the power to the VP-730/731.

Upon initialization, the new VP-730/731 audio software version shows in the Information menu.

About Device Firmware:

Applying a newer firmware version than the one already installed on your unit can bring various enhancements, include workarounds for diverse problems encountered by the device, and improve or add newly developed features.

On the other hand, downgrading the firmware version can recover the device’s functionality in the event of a software update either turning up faulty or causing the unit’s overall performance to drop. However, bear in mind that applying an older firmware isn’t recommended and might not always be possible.

When it comes to the update steps, due to the large variety of devices and numerous ways for installing a new firmware, it is recommended that you carefully read and understand the upgrade steps, and consider applying a different firmware only when you have familiarized yourself with the update method.

As the installation process is most of the times quite risky, this step should be taken by users that have the ability to successfully complete the update; regular users may initiate it at their own risk. Moreover, it’s best that this task be performed in a steady power environment such as the one ensured by a UPS unit.

Therefore, if you consider applying this release, hit the download button, take into account all the aforementioned aspects, and update the device’s firmware. Also make sure you constantly check with our website to ensure that you don’t miss a single new release. 

It is highly recommended to always use the most recent driver version available

Do not forget to check with our site as often as possible in order to stay updated on the latest drivers, software and games

Try to set a system restore point before installing a device driver

This will help if you installed a wrong driver

Problems can arise when your hardware device is too old or not supported any longer

Kramer VP-730 Presentation Scaler-Switcher Firmware 1.2 Audio Bookmark

Hyperlink code:
Hyperlink for Forum code:

Kramer VP-730 Presentation Scaler-Switcher Firmware 1.2 Audio Drivers Download Notice

Top 4 Download periodically updates information of Kramer VP-730 Presentation Scaler-Switcher Firmware 1.2 Audio full driver from the manufacturer, but some information may be slightly out-of-date.

Using warez version of Kramer VP-730 Presentation Scaler-Switcher Firmware 1.2 Audio driver is hazardous. Our driver download links are directly from our mirrors or publisher's website, Kramer VP-730 Presentation Scaler-Switcher Firmware 1.2 Audio torrent files or shared files from free file sharing and free upload services, including Rapidshare, HellShare, HotFile, FileServe, MegaUpload, YouSendIt, MailBigFile, DropSend, MediaMax, zUpload, MyOtherDrive, SendSpace, DepositFiles, Letitbit, LeapFile, DivShare or MediaFire, are not allowed!

It is not recommended to download drivers from illegal sites which distribute a keygens, key generators, pirate keys, serial numbers, warez full versions or cracks for Kramer VP-730 Presentation Scaler-Switcher Firmware 1.2 Audio. These drivers might corrupt your computer installation or breach your privacy. A driver might contain a trojan horse opening a backdoor on your computer. Hackers can use this backdoor to take control of your computer, copy data from your computer or to use your computer to distribute viruses and spam to other people.