BMC version 2.48.ce3e3bd2 implements new password complexity rules

- The Baseboard Management Controller (BMC) firmware version 2.48.ce3e3bd2 implements new BMC Password complexity rules. The default setting for password complexity value is set to Medium.
- In previous BMC firmware version 2.48.89b32e0d (and earlier) no option for complexity rules were available. The equivalent version of enabling password complexity rules on version 2.48.89b32e0d (and earlier) is to Disable password complexity rules on version 2.48.ce3e3bd2.
- The main purpose of the added feature of Password complexity rules, is to prevent setting weak passwords due to security considerations.

Note:

- There is a potential scenario where the user may upgrade to BMC firmware version 2.48.ce3e3bd2 or newer and perform a “BMC Factory default” restoration. This action will enforce the new password rules, setting the complexity to Medium, and forcing the user to follow the new password complexity rules.
- Users must set a password compliant with the selected complexity policy when setting a new password after BMC Factory default.
- If a BMC Factory default is not performed, the system will keep accepting the old password even if it does not comply with the new complexity rules.

Versions:

- BIOS : 22.01.0096
- ME : 04.01.04.423
- BMC : 2.48.ce3e3bd2
- FRUSDR : 0.34

FRUSDR Changes:

- Change KCS sensor name from "KCS Ctrl Mode" to "KCS Policy".
- Change Build package from BUILD 16 to BUILD 18

BMC Changes:

- 2103636075 - [S2600ST] New users created before enabling host interface cannot log on to channel 4's EWS.
- 2103636299 - [S2600ST]the deleted user network privilege still exist in channel 4 when delete a user via channel 3
- 2103636301 - [S2600ST]The new user 's network privilege is invaild in channel4 when create a new user in channel3 with same ID
- 2103637120 - [S2600ST]The update message is shown as "BIOS" when update ME FW via redfish
- 2103637174 - Embedded Web Server: There is a type error in the help document of the "Security Settings" option
- 2103637181 - Embedded Web Server: There is a type error in the "Miscellaneous" ---> "NM Configuration" option
- 2103637119 - [S2600ST]There is a warning messages when click on the BIOS Configurations page immediately after logging in to the EWS.
- 2103636933 - [S2600ST]The KVM delete button on the current users page in the EWS is invalid
- 2103636982 - [S2600ST]The "+-" button of the KVM number bar on the Current Users page in the EWS is invalid
- 2103636945 - [S2600ST]The information of the channel3/4 are lost in EWS when SUT have 4 NIC port in BIOS NIC Configuration
- 1508422943 - [SOW] The display of WebUI host interface(IPV4 page) is not beautiful enough
- 2103635503 - [S2600ST]The contents of the help page for the NIC/Storage information are not displayed correctly.
- 2103635530 - [S2600ST]The warning messages is not displayed correctly when restore BMC with checking "Keep User and LAN configuration".
- 2103635541 - [S2600ST]SDR version will roll back to factory shipping version "D2.48" after restore BMC with checking "Keep User and LAN configuration"
- 2103635552 - User can add duplicate AD group name with different network privilege via EWS.
- 2103635560 - The Network Privilege of the role group show "Reserved" in "Active Directory Settings" page when add a "No Access" role group in Active Directory.
- 2103635568 - [S2600ST]The theme display abnoramlly for the storage information page in EWS
- 2103635708 - [S2600ST]The drop-down menu for the role group privileges of AD in the Chinese EWS is shown in English.
- 2103635717 - [S2600ST]When enable NTP server and set primary NTP server, the warning message is empty or "undefined" in the chinese EWS.
- 2103635730 - [S2600ST]The type for web console show as "N/A" in the "system"->"Current Users" page
- 2103635740 - [S2600ST] the "vMedia Usable" is shown "NO" in the "System" ->"Current Users" page when mount USB device or 'ISO image' as virtual storage in the KVM session
- 2103635746 - [S2600ST]the "vMedia Usable" still show "Yes" in the "System" ->"Current Users" page when pull out all the HTML5 virtual medias
- 2103635748 - [S2600ST]The number of event entries in the "Sensor Specific Events"/"BIOS Generated Events" event category is incorrect
- 2103635803 - [S2600ST][Redfish]When use POST method to create the 6th subscription,the "code" and "message" info in the response are not displayed correctly.
- 2103635845 - [S2600ST][Redfish]When plug out the dedicated LAN cable,the "SpeedMbps" is shown "4294967295" in redfish
- 2103635849 - [S2600ST][Redfish]There are two links to the ethernet interface of channel3 in redfish
- 2103635865 - [S2600ST][Redfish]The response messages display abnormally when use post method to update BMC/BIOS/ME/debug FW via redfish
- 2103635922 - [S2600ST][Redfish]The BMC/BIOS/ME FW can't be downgraded in BMC v2.48b via redfish.
- 2103635924 - [S2600ST]It pops up a warning message when check "Enable HOST Interface".
- 2103635996 - Embedded Web Server: The title bar of "NIC Information" and "Storage Information" still show English when the Web browser set to Chinese language
- 2103636002 - Embedded Web Server: There is a typo error on the “System Information --- Storage Information” menu
- 2103636004 - Embedded Web Server: The help documentation of the “NIC Information” and “Storage Information” shows the “DIMM information” help documentation
- 2103636005 - Embedded Web Server: When mount a media to SUT, on the “Current User” option, the “vMedia Usable” option still shows “No” string.
- 2103636083 - [S2600ST]The HI BMC IP can't be modified when enable LAN failover and set the primary LAN channel to channel-1.
- 2103636295 - [S2600ST][Redfish]The behavior of user with different privilege in Redfish doesn't same with EWS.
- 2103636303 - [S2600ST][Redfish]The "EndTime" of simple update FW is displayed as "1970-01-01T00:00+00:00" when simple update FW via redfish.
- 2103636306 - [S2600ST][Redfish]The "Messages" of simple update FW is empty when simple update FW via redfish
- 2103636461 - Enable the complex password and set the password complexity to "Low", it still can use the "qw12!@" string to the user password
- 2103636476 - Embedded Web Server: The "Enforce Password History" value does not match with its help documentation
- 2103636525 - [STPS2600STThere is a spelling error "interfac" in warning messages when check "enable Host Interface" in Chinese EWS->configuration->IPv4 network or IPv6 network
- 2103636530 - [S2600ST]The "Virtual Media over HTML5" function failed when change HTTPS port to login the EWS
- 2103636533 - [S2600ST]debug console will pop some error messages when click "IPv4 Network"/"IPv6 Network"/"Web ISO" page in the EWS
- 2103636537 - [S2600ST]The primary port can't be modified when issue ipmitool command again to change the primary port.
- 2103636691 - [S2600ST]The example password should not allowed in the help page for high complex password
- 2103636724 - Embedded Web Server: It can not mount the media through the device 1, device 2, device 3 and device 4 options concurrently
- 2207974933 - WebISO feature saves remote system credentials in plain text
- 2209858616 - [S20600WF] Rapid power cycling on leaves power supply in status of 0x0980
- 2103628332 - OFU Utility: When use Gold 6248 2.5GHz CPU, update both BIOS and BMC, it always generate the “Exit Air Temp” UNC and UC event log
- 2103633732 - [S2600ST]The KVM session of the shared IPv6 NIC will be closed automatically after press F10 to save the BIOS setup.
- 2103633363 - Embedded Web Server: Occasionally when you login the EWS with correct username and password, the browser will kick you out of the EWS immediately
- 2103633665 - [S2600ST]It keeps repeating update when update the ME FW via OOB under deny all mode.
- 1508134722 - [Redfish]It keeps repeating update when update the ME/BIOS FW via Redfish under deny all mode.
- 2103633628 - [S2600ST]The SUT will hang up or reboot automitacally after not connectting to the WEB ISO server.
- 1508103258 - BMC Debug log smbios type0 stores wrong BIOS version information

BIOS Changes:

- Hsd-es-id: 2103633496 - [S9200WK] EWS Complex settings will be reset after system reboot.
- Hsd-es-id: 2103633792 - [S9200WK] BIOS Setup-->Main page has setting “POST errors Pause” but EWS BIOS Configurations Main page do not have it
- Hsd-es-id: 2103633816 - [S9200WK] A few typo under "EWS->BIOS configuration->Integrated IO Configuration"page, attached picture show it
- Hsd-es-id: 16011113015 -[S9200WK] modprobe acpi_cpufreq fails in BIOS
- Hsd-es-id: 16011640502 -[S9200WK] In BMC force update mode,the KCS mode of the BIOS setup still show allow all mode in the restricted/deny all mode.

GENERAL INSTALLATION PROCEDURE

1. Unzip the contents of the update package and copy all files to the root directory of a removable media (USB flash drive)
2. Insert the USB flash drive to any available USB port on the system to be updated
3. Power on the server and load the uEFI shell
4. Begin the update process running the Startup.nsh
5. Reboot the system after the update process has successfully completed

Web GUI update

1. Unzip the package onto your system
2. Log into the BMC web GUI
3. Navigate to Configuration, then Firmware Update
4. Click browse, and direct the browser to the location of Purley_1.04.f80688d0.bin
5. Click upload. Progress and status will be shown as the update progresses

UEFI update

1. Unzip package and load onto a flash drive
2. Boot to UEFI shell, and navigate to the folder where this package lives
3. Run fwUpdateBMC.nsh and follow the prompts

Verifying Updates:

01. After the final update has completed successfully, reboot the system
02. During POST, hit the Key when prompted to access the BIOS Setup Utility
03. From the BIOS Setup Utility main menu, hit the key to load BIOS defaults
04. Hit the key to Save Changes and Exit the BIOS defaults
04. At the main menu verify the BIOS revision is correct
05. Move cursor to the SERVER MANAGEMENT menu and hit Enter
06. Move cursor to the SYSTEM INFORMATION Option and hit Enter
07. Verify the BMC Firmware revision is correct
08. Verify the SDR revision is correct
09. Verify the ME Firmware revision is correct
10. Configure desired BIOS Option settings
11. Hit the F10 Key to Save Changes and Exit

About Firmware Updates:

Applying a newer firmware version than the one already installed on your unit can bring various enhancements, include workarounds for diverse problems encountered by the device, and improve or add newly developed features.

On the other hand, downgrading the firmware version can recover the device's functionality in the event of a software update either turning up faulty or causing the unit's overall performance to drop. However, bear in mind that applying an older firmware isn't recommended and might not always be possible.

When it comes to the update steps, due to the large variety of devices and numerous ways for installing a new firmware, it is recommended that you carefully read and understand the upgrade steps, and consider applying a different firmware only when you have familiarized yourself with the update method.

As the installation process is most of the times quite risky, this step should be taken by users that have the ability to successfully complete the update; regular users may initiate it at their own risk. Moreover, it's best that this task be performed in a steady power environment such as the one ensured by a UPS unit.

Therefore, if you consider applying this release, hit the download button, take into account all the aforementioned aspects, and update the device's firmware. Also make sure you constantly check with our website to ensure that you don't miss a single new release.

  It is highly recommended to always use the most recent driver version available.

Try to set a system restore point before installing a device driver. This will help if you installed an incorrect or mismatched driver. Problems can arise when your hardware device is too old or not supported any longer.

Intel S9232WK2HLC Server System BIOS/Firmware 0.34 Bookmark

Hyperlink code:
Hyperlink for Forum code:

Intel S9232WK2HLC Server System BIOS/Firmware 0.34 Drivers Download Notice

Top 4 Download periodically updates information of Intel S9232WK2HLC Server System BIOS/Firmware 0.34 full driver from the manufacturer, but some information may be slightly out-of-date.

Using warez version of Intel S9232WK2HLC Server System BIOS/Firmware 0.34 driver is hazardous. Our driver download links are directly from our mirrors or publisher's website, Intel S9232WK2HLC Server System BIOS/Firmware 0.34 torrent files or shared files from free file sharing and free upload services, including Rapidshare, HellShare, HotFile, FileServe, MegaUpload, YouSendIt, MailBigFile, DropSend, MediaMax, zUpload, MyOtherDrive, SendSpace, DepositFiles, Letitbit, LeapFile, DivShare or MediaFire, are not allowed!

It is not recommended to download drivers from illegal sites which distribute a keygens, key generators, pirate keys, serial numbers, warez full versions or cracks for Intel S9232WK2HLC Server System BIOS/Firmware 0.34. These drivers might corrupt your computer installation or breach your privacy. A driver might contain a trojan horse opening a backdoor on your computer. Hackers can use this backdoor to take control of your computer, copy data from your computer or to use your computer to distribute viruses and spam to other people.