Intel S2600BPB Server Board RSTe Driver 5.5.0.1369 for Server 2012 R2

Intel S2600BPB Server Board RSTe Driver 5.5.0.1369 for Server 2012 R2

Intel S2600BPB Server Board RSTe Driver 5.5.0.1369 for Server 2012 R2 Download Summary

  • File size: 33.80 MB
  • Platform: Windows Server 2012
  • Price: FREE DOWNLOAD
  • Downloads: 79
  • Released: April 02, 2019
  • Manufacturer URL: Intel

Intel S2600BPB Server Board RSTe Driver 5.5.0.1369 for Server 2012 R2

Intel Rapid Storage Technology enterprise (Intel RSTe) package is intended for all customers. Included in this package is Intel Virtual RAID on CPU (Intel VROC) 5.5 Production Version (PV) release, Intel RSTe SATA RAID, and Intel RSTe NVMe RAID. For the Pre-OS environment, Intel VROC UEFI drivers and Intel RSTe SATA UEFI, and Legacy OROM images are included.

Intel Virtual RAID on CPU (Intel VROC) is the term describing Intel RSTe with Intel Volume Management Device (Intel VMD)-enabled NVMe drivers, assisting CPU attached PCIe NVMe SSD bootable RAID.

Note: It is always recommended to update your system BIOS to the included PV release of Pre-OS drivers to take advantage of the most optimal and updated features of each Production Version release.

Changes:

- Updated Intel RSTe 5.5 to remove .NET Framework and Intel ASM from the package

New in Intel RSTe 5.5.0.1369 Release Package:

- To address functional and security updates, this version of the Intel Rapid Storage Technology enterprise (Intel RSTe) 5.5.0.1369 PV Release Package has been updated to remove the Microsoft .NET Framework as well as the Intel Acceleration Storage Manager (ASM). Users should update to the latest version.
- For the customer’s convenience, the Intel RSTe product installation application was designed to automatically install the Microsoft .NET Framework and provide an option to install the Intel Acceleration Storage Manager (ASM).
- The .NET Framework was included because the Intel RSTe user interface relies on the .NET Framework to operate properly. To ensure that customers are able to get the latest version available, Intel is no longer including .NET Framework in the Intel RSTe production package. This is not needed because the supported Windows operating systems already include a version of .NET Framework.
- In addition to removal of the .NET Framework installation, this release also removes the Intel ASM component. The Intel ASM installer has some dependencies on 3rd party libraries and Intel would like to reduce or eliminate these dependencies. Until this is accomplished, the Intel ASM component is being removed.
- For this release, the device drivers and internal tools have not been updated.

Issues Resolved:

- In the UEFI environment SATA RAID does not support Firmware Updates. This affects the Intel Firmware Upgrade Tool (FUT) used by customers when SATA RAID volumes cannot be updated to latest firmware.
- When running in a platform where protocol errors (e.g.R_ERRs) can be encountered during I/O, Intel RSTe may inadvertently mark the drive, corresponding to the connection that encountered the error, as Failed when the drive is operational.
- In the case where Windows 2008 R2 operating system is installed on a SATA device on the SATA or sSATA controller managed by RSTe and a HDD disk is unresponsive on the SCU (SAS) controller also managed by RSTe, the operating system may fail to boot until the unresponsive disk is removed.
- When attempting to resume from an S4 power state with a degraded 3 drive RAID5 volume (as a result of a filed drive), may result in a system failure.
- With Windows 10 RS5 and RSTe SATA driver installed, the system does not resume from S4 correctly
- CSMI command to retrieve RAID information on SATA returns byte-swapped and truncated data
- VROC UEFI Drivers are not Backward compatible
- Having Windows installed on a 4-disk RAID 10 on the SATA controller managed by the RSTe driver, the disk or volume with the operation system may not be marked as the system volume. Consequently, the option to delete the volume is present. Deleting the system volume will cause a blue screen and delete any data on that volume.
- Windows may stuck when one of the RAID5 member drive hot-removal during the RAID5 rebuilding
- Changes in UEFI 5.4 VMD Scan Code Require 5.4 VMD Windows version. No backward compatibilty for Pre-OS.
- On Microsoft Windows 7 64 bit operating system, if both power states S3 (sleep) and S4 (hibernate) are set to be initiated in that order, a blue screen may occur when Windows attempts to resume from S4.
- Changes in UEFI 5.4 VMD Scan Code Require 5.4 VMD Windows version. No backward compatibilty for Pre-OS.
- Using 5.4 VROC RSTCli64.exe tool in WinPE environment,the device cannot be seen
- When running in a configuration where a RAID volume is in a Rebuild state and an I/O stress test is running to that rebuilding RAID volume, the system may reboot.
- In a configuration that includes both SATA and NVMe disks connected to the platform, a SATA disk may appear to have disappeared from both Windows Disk Management and the RSTe GUI after resuming from sleep state S3. This issue was reproduced when Windows 10 64 bit is installed on an NVMe disk connected to PCIe and VMD is not enabled; although it may not be limited to this exact configuration.
- When running in a 2 drive RAID 1 configuration where drive A has encountered many ECC error, removing Drive B and hot inserting a new Drive B can result in drive A becoming Failed (due to the number of Back Blocks) causing the RAID volume to fail. Drive A may then become inaccessible.
- Certain Intel NVMe Devices with custom firmware versions display double device entries in the HII menu
- When VMD is disabled, Intel Virtual Raid on CPU menu option should not be visible in BIOS HII menu.
- System power states testing S3 and enter S4 using power button to wake from S4 causes black screen hang up and sometimes get 0x1E BSOD.
- When running in a configuration where an Intel VROC RAID volume is spanning Intel VMD controllers, if one of the drives is removed the information of the drive being removed may not be properly propagated throughout the platform.Running a tool like "list disk" may still report the missing drive.
- When using the RSTe CLI tool in a WinPE environment or opening a command window within a Windows pre-install process using "Shift-F10", after using the RAID create command to create any RAID array using SATA disks on the SATA or sSATA controller, executing the RSTe CLI information command may fail to return any disk information.
- Some systems do not update the SlotStatus register PresenceDetectedState bit to indicate a hotplug has ocurred. Intel VMD driver gets the interrupt when this Slot Status register is set. This does not occur in Linux because the PCIe Hotplug driver uses LinkStatus DataLinkLayerActive first and then SlotStatus PresenceDetectedState second, so this incorrect setting for the SlotStatus PresenceDetectedState register is ignored.
- In the case where Windows 2008 R2 operating system is installed on a SATA device on the SATA or sSATA controller managed by RSTe and a HDD disk is unresponsive on the SCU (SAS) controller also managed by RSTe, the operating system may fail to boot until the unresponsive disk is removed.
- When running on a system with Windows Server 2016, in a configuration where the system may repeatedly restart, a 0x9F System Error may be encountered.
- There are two entries on some customer platforms and when booting, the system may hang
- On a platform that has HDD devices connected to the SATA controller and Windows 10 RS3 operating system installed on either a single HDD or multiple in a RAID volume made up of those HDD devices, the platform may hang when entering S4 hibernate sleep state if there is also an eSATA device connected to the same SATA controller.
- Intel VROC UEFI driver is returning unexpected values for RouteConfig Conformance and ExtractConfigFunction for SCT 2.6 version UEFI Test cases.
- In Windows OS with RAID 5, a new NVMe device is hot inserted and the UI allows user to select "Change mode" in RWH mode property and choose the system disk as Journaling Drive to Close RAID Write Hole. System Disk should never be allowed

To install this package please do the following:

- Save the downloadable package on an accessible location (such as your desktop).
- Unzip the file and enter the newly-created directory.
- Locate and double-click on the available setup file.
- Allow Windows to run the file (if necessary).
- Read EULA (End User License Agreement) and agree to proceed with the installation process.
- Follow the on-screen instructions.
- Close the wizard and perform a system reboot to allow changes to take effect.

About RST (Rapid Storage Technology) Drivers:

Once Intel's Rapid Storage Technology (RST) driver is applied, desktop and notebook systems will be able to manage the available storage (one or more drives) more easily.

And that's not all you should expect: updating the RST version can also bring about improved storage performance, lower power consumption, faster boot times, quicker data reads, as well as several other changes.

As far as applying this release is concerned, simply make sure your system configuration is compatible with this package, run the available setup, and follow the on-screen instructions for a complete installation. In addition to that, don't forget to perform a reboot to make sure that all changes take effect properly.

Even though other operating systems might be compatible as well, we do not recommend installing this package on platforms other than the specified ones.

With this in mind, click the download button, and get and apply the present version. Also, check with our website as often as possible in order to stay up to date with latest releases.

Intel S2600BPB Server Board RSTe Driver 5.5.0.1369 for Server 2012 R2 Bookmark

Hyperlink code:
Hyperlink for Forum code:

Intel S2600BPB Server Board RSTe Driver 5.5.0.1369 for Server 2012 R2 Drivers Download Notice

Top 4 Download periodically updates information of Intel S2600BPB Server Board RSTe Driver 5.5.0.1369 for Server 2012 R2 full driver from the manufacturer, but some information may be slightly out-of-date.

Using warez version of Intel S2600BPB Server Board RSTe Driver 5.5.0.1369 for Server 2012 R2 driver is hazardous. Our driver download links are directly from our mirrors or publisher's website, Intel S2600BPB Server Board RSTe Driver 5.5.0.1369 for Server 2012 R2 torrent files or shared files from free file sharing and free upload services, including Rapidshare, HellShare, HotFile, FileServe, MegaUpload, YouSendIt, MailBigFile, DropSend, MediaMax, zUpload, MyOtherDrive, SendSpace, DepositFiles, Letitbit, LeapFile, DivShare or MediaFire, are not allowed!

It is not recommended to download drivers from illegal sites which distribute a keygens, key generators, pirate keys, serial numbers, warez full versions or cracks for Intel S2600BPB Server Board RSTe Driver 5.5.0.1369 for Server 2012 R2. These drivers might corrupt your computer installation or breach your privacy. A driver might contain a trojan horse opening a backdoor on your computer. Hackers can use this backdoor to take control of your computer, copy data from your computer or to use your computer to distribute viruses and spam to other people.