Intel R2312WFTZS Server System OFU Firmware 00.001.0015

Intel R2312WFTZS Server System OFU Firmware 00.001.0015

Intel R2312WFTZS Server System OFU Firmware 00.001.0015 Download Summary

  • File size: 34.40 MB
  • Platform: OS Independent
  • Price: FREE DOWNLOAD
  • Downloads: 157
  • Released: November 27, 2018
  • Manufacturer URL: Intel

Intel R2312WFTZS Server System OFU Firmware 00.001.0015

Versions:

- BIOS : 00.01.0015
- ME : 04.00.04.340
- BMC : 1.74.ee39402a
- FRUSDR : 1.74

Changes in BIOS R00.01.0015:

- Rename BIOS ID from X0168 to R0015
- Clone from HSD - Security VT - PCH UEFI FW shall delay PCI Bus Master Enable (PCICMD.BME) until end of POST to prevent DMA attacks on UEFI FW in RAM.
- [S2600BP] SEL error during AC cycling: IPMI Watchdog reports the watchdog initiated a hard reset.
- There is no SEL log generate when flash BIOS and ME version which same as SUT version.
- BIOS: Purley Post -SRA feature: OOB Update and Config.
- [PC Production] Sync Skylake Production code to PC Production.(5387193:Need Updated BIOS for External Use to Resolve P2P Issue)
- FW-UEFI-Vuln-2018-031 - Dynamic loops accessing one element beyond boundary due to <= operator.
- [PC Stitching]Update ESRTIISataEFi version to 05140000.
- PSIRT-FW-UEFI-Vuln-2018-040 SvSmmHandler SMI call-out.
- [S2600BP]MTT CPU1/MTT CPU2 sensors show no reading when run AC cycles and can't recovery within 300s[Only path for this issue,not a final solution].
- [S2600BP]SUT hang post screen when run DC cycles.
- [S2600BP]HSTI is absent on Windows Server 2016.
- SUT will hang up on 0x9D after installed NIC card-X550 and enable RSD.
- Update BIOS X0155 SEL LOG BIOS ID is wrong,it show 20.01.0155.
- DIMM LED(chX) turns off after another correctable error is injected to a DIMM in different Channel(chY)-V01.
- RSD 2.2-SMBIOS Type 199 had zeros value for port 3 and 4 for PCIe Cable ERROR Data.
- Random Machine Check failure QPI Phy init abort during reboot reported on S2600ST.
- After CE injection,fault DIMM LED remains asserted despite follow up reset shows healthy memory subsystem-V02.
- [Purley BIOS]SOL function terminal type need to support more terminal types the same as console redirection types
- [Purley] Add BIOS options in ITK to change USB 2.0 ports equalization parameters
- Add Factory BIOS flag and .Factory string to SMBIOS Type 0
- [Purley BIOS]UPI latency performance parameters which impact bandwidth and latency to be exposed in setup/ITK/syscfg
- [S2600BP] Warning SEL during AC Cycling: BMC FW Health reports SSB Temp has failed and may not be providing a valid reading
- Integration BIOS ACM to 1.3.7 and SINIT to 1.3.4
- [S2600ST]VMD enable in BIOS is mismatch with motherboard NVME SSD
- [Purley BIOS]Extend option value range for Memory Correctable Error Threshold
- ME update failed for X0148 online update to 0D.01.0008

Changes in BMC v1.74.ee39402a:

- OEM Get reading command isn't workable
- [S2600BP] Exit Air Temp SEL events seen during OS Install and AC Cycling
- PCIe register access from host can be remapped to any base address into BMC address space.
- SPS FW Command Filtering
- [S2600BP] OpenIPMI driver fails to detect BMC on startup
- [redfish]UpdateMe Error with biospack 0D010125
- Baseboard FRU information missing with Redfish Schema
- [iKVM over HTML5]Up and Down key can control HTML5 iKVM session menu and BIOS setup menu in the same time
- [S2600WF] The threshold info will disappear after change sensor owner.
- [S2600BP] Exit Air Temp SEL events seen during OS Install and AC Cycling
- [OOB BIOS Configuration]the actual value is different with the value you click to change after do change value steps
- [iKVM over HTML5]Virtual media will be terminated when refresh the session of Virtual Media over HTML5 by press "F5"
- [S2600WF]Control BMC Services command sometimes cannot disable BMC Services
- [S2600WF] The button of Launch KVM over HTML5 not gray out when use operator user.
- [S2600WF] PSU redundancy lost event not showing after remove power supply cable
- [S2600BT] PSU redundancy lost event Not showed after remove power supply cable
- [OOB BIOS Configuration]Some variable show in EWS BIOS configuration but can’t map it in BIOS setup menu.
- Redfish ComputerSystem node has invalid field
- [iKVM over HTML5]When changed the language from English to Chinese, there always some English characters in the session
- PCIe register access from host can be remapped to any base address into BMC address space.
- SPS FW Command Filtering
- [S2600BP][Q2] OpenIPMI driver fails to detect BMC on startup
- Baseboard FRU information missing with Redfish Schema
- S2600BP: Use BMC_1.71 or 1.72 and S2600BPS mainboard, after updating the FruSdr_1.37, some sensors in EWS shows "unavailable" or incorrect reading
- [S2600BP LCR]NVME 1 Therm Mgn sensor show no reading when run AC/DC cycles and can't recovery within 300s
- [iKVM over HTML5]It will show "SecurityResult Failed(Retry after 30 sec or iKVM reset)" if we launch the 5th ikvm session
- [S2600ST] IPMI command to get fan speed not working on CPU fans
- [S2600BP][Q2] OpenIPMI driver fails to detect BMC on startup
- [S2600BT] EWS help page show 404 about Virtual Media over HTML5
- Baseboard FRU information missing with Redfish Schema
- [OOB BIOS Configuration]Some variable show in EWS BIOS configuration but can’t map it in BIOS setup menu.
- [HTML5 KVM] No error or warning message displayed when 5th HTML5 KVM is opened, but the session is blank.
- CCB1964(PSME 2.2 support in BMC 1.57) doesn't align with PSME restful API specification
- Q3'18 #CCB2447 [Purley BMC]HTML5 support
- [HTML5 KVM] No error or warning message displayed when 5th HTML5 KVM is opened, but the session is blank.
- [S2600BT]Access still be denied after unmounted USB disk from rKVM
- [S2600WF]Seneor report PWR Unit Redundancy lost with FCT SDR
- [redfish]URL spelling error ,bios settings
- [iKVM over HTML5]When changed the language from English to Chinese, there always some English characters in the session
- [HTML5 KVM] 'Options' and 'User List' menu are always greyed out in the HTML5 KVM
- [HTML5 KVM] 'Defined Macros' option disabled in Keyboard Macro menu, hence the user added keyboard macros in EWS->Configuration page also not getting reflected.
- [HTML5 Virtual Media] Java Virtual media supports 4 devices whereas HTML5 Virtual media supports only 3
- FRUSDR update via EWS fails with BMC 1.71
- [S2600BT] No "start" and "completed" in FW update event description
- The warning messages of "restore system defaults" doesn't match test case.
- [S2600BT] SDR parse failed after press "Parse" button in EWS SDR configuration page.
- On-Line Update the firmware (such as BMC or ME), the event log does not show the "update process" clearly
- [S2600BT] EWS help page show 404 about Virtual Media over HTML5
- Unable to enable SSH using Redfish Schema
- Redfish DMTF schema does not have a Bios/Settings XML field
- Q3'18 #CCB2202[BMC]Need log to track user/IP logins to BMC
- [S2600WF] PSOC on rear HSBP becoming corrupted
- Use Windows Client PC, mount a USB Flash then un-mount it later, the USB Flash could not be accessed on the Client PC

Changes in FRUSDR 1.74:

- SDR record failure

GENERAL INSTALLATION PROCEDURE

1. Unzip the contents of the update package and copy all files to the root directory of a removable media (USB flash drive)
2. Insert the USB flash drive to any available USB port on the system to be updated
3. Power on the server and load the uEFI shell
4. Begin the update process running the Startup.nsh
5. Reboot the system after the update process has successfully completed

Web GUI update

1. Unzip the package onto your system
2. Log into the BMC web GUI
3. Navigate to Configuration, then Firmware Update
4. Click browse, and direct the browser to the location of the .bin file
5. Click upload. Progress and status will be shown as the update progresses

UEFI update

1. Unzip package and load onto a flash drive
2. Boot to UEFI shell, and navigate to the folder where this package lives
3. Run fwUpdateBMC.nsh and follow the prompts

Verifying Updates:

01. After the final update has completed successfully, reboot the system
02. During POST, hit the Key when prompted to access the BIOS Setup Utility
03. From the BIOS Setup Utility main menu, hit the key to load BIOS defaults
04. Hit the key to Save Changes and Exit the BIOS defaults
04. At the main menu verify the BIOS revision is correct
05. Move cursor to the SERVER MANAGEMENT menu and hit Enter
06. Move cursor to the SYSTEM INFORMATION Option and hit Enter
07. Verify the BMC Firmware revision is correct
08. Verify the SDR revision is correct
09. Verify the ME Firmware revision is correct
10. Configure desired BIOS Option settings
11. Hit the F10 Key to Save Changes and Exit  

About Firmware Updates:

Applying a newer firmware version than the one already installed on your unit can bring various enhancements, include workarounds for diverse problems encountered by the device, and improve or add newly developed features.

On the other hand, downgrading the firmware version can recover the device's functionality in the event of a software update either turning up faulty or causing the unit's overall performance to drop. However, bear in mind that applying an older firmware isn't recommended and might not always be possible.

When it comes to the update steps, due to the large variety of devices and numerous ways for installing a new firmware, it is recommended that you carefully read and understand the upgrade steps, and consider applying a different firmware only when you have familiarized yourself with the update method.

As the installation process is most of the times quite risky, this step should be taken by users that have the ability to successfully complete the update; regular users may initiate it at their own risk. Moreover, it's best that this task be performed in a steady power environment such as the one ensured by a UPS unit.

Therefore, if you consider applying this release, hit the download button, take into account all the aforementioned aspects, and update the device's firmware. Also make sure you constantly check with our website to ensure that you don't miss a single new release.

Intel R2312WFTZS Server System OFU Firmware 00.001.0015 Bookmark

Hyperlink code:
Hyperlink for Forum code:

Intel R2312WFTZS Server System OFU Firmware 00.001.0015 Drivers Download Notice

Top 4 Download periodically updates information of Intel R2312WFTZS Server System OFU Firmware 00.001.0015 full driver from the manufacturer, but some information may be slightly out-of-date.

Using warez version of Intel R2312WFTZS Server System OFU Firmware 00.001.0015 driver is hazardous. Our driver download links are directly from our mirrors or publisher's website, Intel R2312WFTZS Server System OFU Firmware 00.001.0015 torrent files or shared files from free file sharing and free upload services, including Rapidshare, HellShare, HotFile, FileServe, MegaUpload, YouSendIt, MailBigFile, DropSend, MediaMax, zUpload, MyOtherDrive, SendSpace, DepositFiles, Letitbit, LeapFile, DivShare or MediaFire, are not allowed!

It is not recommended to download drivers from illegal sites which distribute a keygens, key generators, pirate keys, serial numbers, warez full versions or cracks for Intel R2312WFTZS Server System OFU Firmware 00.001.0015. These drivers might corrupt your computer installation or breach your privacy. A driver might contain a trojan horse opening a backdoor on your computer. Hackers can use this backdoor to take control of your computer, copy data from your computer or to use your computer to distribute viruses and spam to other people.