Intel S7200APL Server Board Firmware 01.02.0072

Intel S7200APL Server Board Firmware 01.02.0072

Intel S7200APL Server Board Firmware 01.02.0072 Download Summary

  • File size: 13.80 MB
  • Platform: OS Independent
  • Price: FREE DOWNLOAD
  • Downloads: 161
  • Released: May 28, 2017
  • Manufacturer URL: Intel

Intel S7200APL Server Board Firmware 01.02.0072

Versions

:

- System BIOS - R01.02.0072

- ME Firmware - 03.01.03.022.0

- BMC Firmware - 01.012.10645

- FRUSDR - 1.25

BIOS 01.02.0072 Changes:

- Fixed Get "get_platform_config: Config bitmap corrupted/uninitialized messages" in dmesg for both hfi1 ports with integrated fabric.

- Add the stitch support for AdamPass

- Update KNL Ref. Code revision to v01.57.01.00

- Update ME firmware version to SPS_PHI_03.01.03.022.0

- Add B0 CPU signed external ucode patch 0x0000_01ac.

- Update KNL-F Host Fabric Interface UEFI Driver to reversion v1.3.4.0.0

BMC 01.02.10645 Changes:

- Critical Power Supply current events in the System Event Log.

- The information in EWS can't display as Chinese.

- After stress test,there is BMC HW watchdog timer triggered related SEL on SUT.

- Grantley FW Java certificate expired.

- Fix EWS issue that webpage left navigator lane disappeared via clicking "refresh" on popup menu.

- Fix issue of KVM jar signing certificate expiration.

- An error pop-up when selecting EWS option "SDR Configuration" or "Security Settings" with a user privilege account.

- fail to return correct value for PHI card IPMI command.

- [Grantley][BMC][EWS] The "Save" button will be inactive after cancel the modification of Mouse Mode Setting in EWS.

- [Grantley][BMC][EWS] The modification of "Security Settings" and "SDR Configuration" can't be saved in EWS.

- [Grantley][BMC][EWS] The "SDR Configuration" page in EWS can't show any information about SUT.

- Fix KVM issue that start menu will popup on SUT occasionally when check "hold on" of Right/Left Windows key in rKVM.

- Fix content in EWS help info according to test case requirement.

- [Grantley][BMC][EWS] Some EWS help texts (which should not be viewed by user account) will be displayed with user privilege.

- [Grantley][BMC][EWS]The "Node Manager" help texts in EWS.

- OpenSSL is updated from 1.0.2.j to 1.0.2.k.

- OpenSsh is updated from 7.3 to 7.4.

- Fix Smash issue when running smash command.

FRUSDR 1.25 Changes:

- frusdr.efi and ipmi.efi are updated to v14.0 Build 9.

- Domain 6 fan failure value which should have been updated in FRUSDR 122 (based on FSC spreadsheet 0.83) but was missed.

- Temperature threshold updates for the following sensors: Inlet Temp, BMC Temp, P1 VR Temp, Mem VR Temp, HSBP Temp, HSBP PSOC Temp, SSB Temp, Exit Air Temp, Riser1 Temp, Riser2 Temp.

UEFI iFlash32 Installation:

1. Boot the system to EFI Shell

2. Copy IFlash32.efi, ipmi.efi and BIOS.CAP file to a USB Flash Drive ( Do not use the *Rec.CAP file as it will clear the NVRAM) Notes: It is recommended to copy full package

3. Map the respective storage device in the system with the command Shell> map -r

4. Change the Shell to mapped device file system. Example: Shell> fs0: (or fs1:)

5. Run the IFlash32 utility at the prompt fs0:> IFlash32 [File Name] /u /ni

6. Either reboot the system and Go into BIOS setup , reset defaults and save or After the BIOS update and before rebooting, run: fS0:> Iflash32 -rd

7. Reboot the system

Backup BIOS update instructions:

1. Boot the system to EFI Shell

2. Copy IFlash32.efi, ipmi.efi and BIOS .CAP file to a USB Flash Drive ( Do not use the Rec.CAP file as it will clear NVRAM). Notes: It is recommended to copy full package

3. Map the respective storage device in system with the command Shell> map -r

4. Change the Shell to mapped device file system. Example: Shell> fs0: (or fs1:)

5. Run the IFlash32 utility on the prompt fs0:> IFlash32 -u [File Name] UpdateBackupBios -ni

6. It will update primary BIOS with processed capsule, and the backup BIOS update will be completed in next normal boot.

7. Reboot the system.

About ME Firmware:

If you wish to apply this ME (Management Engine) Firmware version, you should first make sure that the version number matches your AMT (Active Management Technology) family, as each update is specifically developed for certain system configurations.

While this technology is mostly associated with enterprises, it can also be used by various IT administrators as well as regular users. However, bear in mind that even though other platforms might also be compatible, we do not recommend installing this release on OSes other than the specified ones.

In order to apply this package, it would be best if you carefully read and understand the instructions provided by your computer manufacturer, and perform the update only when you have completely familiarized yourself with the steps.

In addition to that, make sure you perform a system reboot after upgrading the firmware version in order to allow all changes to take effect properly.

About OS Independent BIOS:

Although installing a newer BIOS version might add new features, update various components, or improve the device’s usability, this process is very risky, so the upgrade is recommended to be performed only when it is really needed.

In addition to that, this task should be performed by someone who has the knowledge to successfully complete the installation; regular users may fulfill it at their own risk.

When it comes to applying a new version without taking into account the computer’s operating system, the most commonly used method to flash the BIOS is by creating a bootable USB or CD containing the update file, and running it from DOS.

Still, regardless of the method used or whether the upgrade is performed by a regular or power user, it’s recommended that the new BIOS be applied in a steady power environment such as the one ensured by a UPS unit.

The Basic Input/Output System (BIOS) is a very important software that loads the currently installed OS, and tests all of the system’s hardware components – so make sure you flash it correctly.

Bear in mind that failing to perform a successful installation could seriously damage your device, and the faulty BIOS resulted from the process might even render it unusable.

About Firmware Updates:

Applying a newer firmware version than the one already installed on your unit can bring various enhancements, include workarounds for diverse problems encountered by the device, and improve or add newly developed features.

On the other hand, downgrading the firmware version can recover the device’s functionality in the event of a software update either turning up faulty or causing the unit’s overall performance to drop. However, bear in mind that applying an older firmware isn’t recommended and might not always be possible.

When it comes to the update steps, due to the large variety of devices and numerous ways for installing a new firmware, it is recommended that you carefully read and understand the upgrade steps, and consider applying a different firmware only when you have familiarized yourself with the update method.

As the installation process is most of the times quite risky, this step should be taken by users that have the ability to successfully complete the update; regular users may initiate it at their own risk. Moreover, it’s best that this task be performed in a steady power environment such as the one ensured by a UPS unit.

Therefore, if you consider applying this release, hit the download button, take into account all the aforementioned aspects, and update the device’s firmware. Also make sure you constantly check with our website to ensure that you don’t miss a single new release.

Intel S7200APL Server Board Firmware 01.02.0072 Bookmark

Hyperlink code:
Hyperlink for Forum code:

Intel S7200APL Server Board Firmware 01.02.0072 Drivers Download Notice

Top 4 Download periodically updates information of Intel S7200APL Server Board Firmware 01.02.0072 full driver from the manufacturer, but some information may be slightly out-of-date.

Using warez version of Intel S7200APL Server Board Firmware 01.02.0072 driver is hazardous. Our driver download links are directly from our mirrors or publisher's website, Intel S7200APL Server Board Firmware 01.02.0072 torrent files or shared files from free file sharing and free upload services, including Rapidshare, HellShare, HotFile, FileServe, MegaUpload, YouSendIt, MailBigFile, DropSend, MediaMax, zUpload, MyOtherDrive, SendSpace, DepositFiles, Letitbit, LeapFile, DivShare or MediaFire, are not allowed!

It is not recommended to download drivers from illegal sites which distribute a keygens, key generators, pirate keys, serial numbers, warez full versions or cracks for Intel S7200APL Server Board Firmware 01.02.0072. These drivers might corrupt your computer installation or breach your privacy. A driver might contain a trojan horse opening a backdoor on your computer. Hackers can use this backdoor to take control of your computer, copy data from your computer or to use your computer to distribute viruses and spam to other people.