Intel R1304SP2SHOC Server System UEFI Firmware 2.06.0006

Intel R1304SP2SHOC Server System UEFI Firmware 2.06.0006

Intel R1304SP2SHOC Server System UEFI Firmware 2.06.0006 Download Summary

  • File size: 27.60 MB
  • Platform: OS Independent
  • Price: FREE DOWNLOAD
  • Downloads: 95
  • Released: August 08, 2017
  • Manufacturer URL: Intel

Intel R1304SP2SHOC Server System UEFI Firmware 2.06.0006

Versions:

- System BIOS - 02.06.0006

- ME Firmware - 02.01.07.328

- BMC Firmware - 01.28.10603

- FRUSDR - 1.04

BIOS R02.06.0006 Changes:

- Fixed: "ID_NET_NAME_ONBOARD=eno1" is the same for two onboard NICs which should be different.

BMC 01.28.10603 Changes:

- EPSD100254304: BMC alerts received in an email via SMTP have a different time

- Enable homepage by default to fix security issue of non-ssl password

- Upgrade psoc to version 1.10

- Upgrade openssl to 1.0.2k

- Upgrade openssh to 7.4p1

- Fix several vulnerability issues in Nessus/Qualys/Trustwave/ZAP scan reports, 1) Web Server Vulnerable to Redirection Page Cross-Site Scripting Attacks; 2) Incomplete or No Cache-control and Pragma HTTP Header Set; 3) Fix SSL Certificate Signed Using Weak Hashing Algorithm and SSL Certificate expiration; 4) Web Server HTTP Header Memory Exhaustion DoS. 5) Web Browser XSS Protection Not Enabled; 6) Incomplete or No Cache-control and Pragma HTTP Header Set; 7) X-Content-Type-Options Header Missing.

Standard Update Procedure from the embedded EFI Shell:

- Unzip the contents of the update package and copy all files to a folder on a USB flash drive

- Insert the USB flash drive to any available USB port on the server system to be updated

- Boot the Server to the EFI shell. This can be accessed via the BIOS setup utility during POST.

- Run the command "map -r" in the EFI shell to mount the USB flash drive

- Run the command "fs0:" to change folders to the USB flash drive. The USB flash drive

may also mount to fs1: depending on other installed devices. The number of "fs#" is

dependent on the result of command "map -r"

- Change folders to the folder storing the update package files

- Run the command "Startup.nsh" to start updating all the firmware and BIOS updates

Warning:

- Do NOT reboot or remove power from your system during the update process. Doing so may render your system inoperable. !!

Verifying updates:

- Reboot the system

- During POST, hit the Key when prompted to access the BIOS Setup Utility

- Hit the F9 key to load BIOS Defaults

- At the MAIN menu verify the BIOS revision is correct

- Move cursor to the SERVER MANAGEMENT Menu

- Move cursor down to the SYSTEM INFORMATION Option and hit Enter

- Verify the BMC Firmware revision is correct

- Verify the SDR revision is correct

- Verify the ME Firmware revision is correct

- Hit the F10 Key to save changes and Exit

Individual Firmware Update Procedure:

If you want to update firmware components individually, like BMC/BIOS/ME/FRUSDR, do NOT run the "STARTUP.NSH" file described in the Standard Update Procedure above. Instead, run the individual .NSH script file for each update included in the update package files. Follow the update order below to ensure a trouble free update:

1) BMC firmware update

2) BIOS update

3) Manageability Engine (ME) Firmware update

4) FRUSDR update

Update BMC Firmware

1) Boot the system to the EFI shell and go to root folder

2) At the shell prompt, run "UpdateBMC.nsh" to start BMC Firmware update

3) When complete, go to the BIOS update section described below, or power off the system and cycle AC power before continuing.

Update System BIOS

1) Boot the system to the EFI shell and go to root folder

2) At the shell prompt, run "UpdateBIOS.nsh" to start BIOS update

3) When complete, reboot the system and enter BIOS Setup by pressing the F2 Key during POST

4) Verify the BIOS string on main BIOS menu

5) Press F9 to load defaults and press F10 to save and reset the system

6) Go to the ME firmware update section described below. The BIOS update is complete. Either reboot the server or go to the ME firmware Update section described below.

Update ME Firmware

1) Boot the system to the EFI shell and go to root folder

2) At the shell prompt, run "UpdateME.nsh" to start ME firmware update

3) When complete, go to the FRUSDR update section described below, or power off the system and cycle AC power before continuing.

Update FRUSDR

1) Boot the system to the EFI shell and go to root folder

2) At the EFI command prompt, run "UpdateFRUSDR.nsh" to start FRUSDR update

3) Answer questions and enter desired information when prompted.

4) When complete, reboot the system by front control panel

Verifying updates

- Reboot the server

- During POST, hit the Key when prompted to access the BIOS Setup Utility

- Hit the F9 key to load BIOS Defaults

- At the MAIN menu verify the BIOS revision is correct

- Move cursor to the SERVER MANAGEMENT Menu

- Move cursor down to the SYSTEM INFORMATION Option and hit Enter

- Verify the BMC Firmware revision is correct

- Verify the SDR revision is correct

- Verify the ME Firmware revision is correct

- Hit the F10 Key to save changes and Exit

- The System Software Update is Complete.

About Firmware Updates:

Applying a newer firmware version than the one already installed on your unit can bring various enhancements, include workarounds for diverse problems encountered by the device, and improve or add newly developed features.

On the other hand, downgrading the firmware version can recover the device's functionality in the event of a software update either turning up faulty or causing the unit's overall performance to drop. However, bear in mind that applying an older firmware isn't recommended and might not always be possible.

When it comes to the update steps, due to the large variety of devices and numerous ways for installing a new firmware, it is recommended that you carefully read and understand the upgrade steps, and consider applying a different firmware only when you have familiarized yourself with the update method.

As the installation process is most of the times quite risky, this step should be taken by users that have the ability to successfully complete the update; regular users may initiate it at their own risk. Moreover, it's best that this task be performed in a steady power environment such as the one ensured by a UPS unit.

Therefore, if you consider applying this release, hit the download button, take into account all the aforementioned aspects, and update the device's firmware. Also make sure you constantly check with our website to ensure that you don't miss a single new release.

Intel R1304SP2SHOC Server System UEFI Firmware 2.06.0006 Bookmark

Hyperlink code:
Hyperlink for Forum code:

Intel R1304SP2SHOC Server System UEFI Firmware 2.06.0006 Drivers Download Notice

Top 4 Download periodically updates information of Intel R1304SP2SHOC Server System UEFI Firmware 2.06.0006 full driver from the manufacturer, but some information may be slightly out-of-date.

Using warez version of Intel R1304SP2SHOC Server System UEFI Firmware 2.06.0006 driver is hazardous. Our driver download links are directly from our mirrors or publisher's website, Intel R1304SP2SHOC Server System UEFI Firmware 2.06.0006 torrent files or shared files from free file sharing and free upload services, including Rapidshare, HellShare, HotFile, FileServe, MegaUpload, YouSendIt, MailBigFile, DropSend, MediaMax, zUpload, MyOtherDrive, SendSpace, DepositFiles, Letitbit, LeapFile, DivShare or MediaFire, are not allowed!

It is not recommended to download drivers from illegal sites which distribute a keygens, key generators, pirate keys, serial numbers, warez full versions or cracks for Intel R1304SP2SHOC Server System UEFI Firmware 2.06.0006. These drivers might corrupt your computer installation or breach your privacy. A driver might contain a trojan horse opening a backdoor on your computer. Hackers can use this backdoor to take control of your computer, copy data from your computer or to use your computer to distribute viruses and spam to other people.